Kapton Insulated Copper Thermocouple Wire

Kapton Insulated Copper Thermocouple Wire
Details:
Fused kapton tape applied to conductor and jacket . Thermocouple wire type J, K, T, E, N . Thermocouple extension wire type JX, KX, TX, EX, NX . Kapton wire is not color-coded . Excellent moisture & abrasion resistance . High dielectric strength
Send Inquiry
Description
Send Inquiry

Fused kapton tape applied to conductor and jacket 
. Thermocouple wire type J, K, T, E, N 
. Thermocouple extension wire type JX, KX, TX, EX, NX 
. Kapton wire is not color-coded 
. Excellent moisture & abrasion resistance 
. High dielectric strength

Model explanation

 

1  Calibration: KX/K, JX/J, TX/T, EX/E, NX/N
2  Insulation: KAPTON
3  Jacket: KAPTON
4  Wire size: 20, 24, 26, 28AWG
5  "S" means "Stranded"; "Blank" means "Solid"

Order code:

Type

Wire
Size(AWG)

Diameter (mm)

Conductor

Calibration

Type J

Type K

Type T

Type E

Extension wire

20

1/0.80

Solid

JX-KPT-KPT-20

KX-KPT-KPT-20

TX-KPT-KPT-20

EX-KPT-KPT-20

20 7/28

7/0.30

Stranded

JX-KPT-KPT-20S

KX-KPT-KPT-20S

TX-KPT-KPT-20S

EX-KPT-KPT-20S

24

1/0.50

Solid

JX-KPT-KPT-24

KX-KPT-KPT-24

TX-KPT-KPT-24

EX-KPT-KPT-24

24 7/32

7/0.20

Stranded

JX-KPT-KPT-24S

KX-KPT-KPT-24S

TX-KPT-KPT-24S

EX-KPT-KPT-24S

26

1/0.40

Solid

JX-KPT-KPT-26

KX-KPT-KPT-26

TX-KPT-KPT-26

EX-KPT-KPT-26

26 7/34

7/0.16

Stranded

JX-KPT-KPT-26S

KX-KPT-KPT-26S

TX-KPT-KPT-26S

EX-KPT-KPT-26S

28

1/0.32

Solid

JX-KPT-KPT-28

KX-KPT-KPT-28

TX-KPT-KPT-28

EX-KPT-KPT-28

28 7/36

7/0.13

Stranded

JX-KPT-KPT-28S

KX-KPT-KPT-28S

TX-KPT-KPT-28S

EX-KPT-KPT-28S

 

Type

Wire
Size(AWG)

Diameter (mm)

Conductor

Calibration

Type J

Type K

Type T

Type E

Thermocouple wire

20

1/0.80

Solid

J-KPT-KPT-20

K-KPT-KPT-20

T-KPT-KPT-20

E-KPT-KPT-20

20 7/28

7/0.30

Stranded

J-KPT-KPT-20S

K-KPT-KPT-20S

T-KPT-KPT-20S

E-KPT-KPT-20S

24

1/0.50

Solid

J-KPT-KPT-24

K-KPT-KPT-24

T-KPT-KPT-24

E-KPT-KPT-24

24 7/32

7/0.20

Stranded

J-KPT-KPT-24S

K-KPT-KPT-24S

T-KPT-KPT-24S

E-KPT-KPT-24S

26

1/0.40

Solid

J-KPT-KPT-26

K-KPT-KPT-26

T-KPT-KPT-26

E-KPT-KPT-26

26 7/34

7/0.16

Stranded

J-KPT-KPT-26S

K-KPT-KPT-26S

T-KPT-KPT-26S

E-KPT-KPT-26S

28

1/0.32

Solid

J-KPT-KPT-28

K-KPT-KPT-28

T-KPT-KPT-28

E-KPT-KPT-28

28 7/36

7/0.13

Stranded

J-KPT-KPT-28S

K-KPT-KPT-28S

T-KPT-KPT-28S

E-KPT-KPT-28S

Note: The products referenced above represent the most popular constructions. Other constructions can be manufactured to meet individual specification and application requirements.

 

Outer shield 
All above thermocouple wire and thermocouple extension wire also can be finished with a metal outer shield to give added protection from abrasion and mechanical damage. If you need the wire with a outer shield, please add "SSB or TCB" to the order code, such as "JX-KPT-KPT-SSB-20S", it means Type JX, 20AWG, Stranded, Insulation: KAPTON, Jacket: KAPTON, Outer shield: Stainless steel. 

Color Code & Initial Calibration Tolerance for Thermocouple Extension Wire:

Thermocouple extension type

ANSI Color Code

Initial Calibration Tolerances

Wire Alloys

Calibration

Conductor (+/-)

Jacket

Temperature Range

Standard
Limits

Special
Limits

Iron (+) vs.  Constantan(-)

JX

Non color-coded

Non color-coded

0°C to +200°C

± 2.2°C

± 1.1°C

Chromel (+) vs.  Alumel (-)

KX

Non color-coded

Non color-coded

0°C to +200°C

± 2.2°C

± 1.1°C

Copper(+) vs. Constantan(-)

TX

Non color-coded

Non color-coded

-60°C to +100°C

± 1.1°C

± 0.5°C

Chromel(+) vs. Constantan(-)

EX

Non color-coded

Non color-coded

0°C to +200°C

± 1.7°C

± 1.1°C

Nirosil (+) vs. Nisil (-)

NX

Non color-coded

Non color-coded

0°C to +200°C

± 2.2°C

± 1.1°C

Copper (+) vs. Alloy 11 (-)

RX/SX

Non color-coded

Non color-coded

0°C to +200°C

± 5°C

-

Copper S (+) vs. -Copper E (-)

BX

Non color-coded

Non color-coded

0°C to +200°C

± 3.7°C

-


Color Code & Initial Calibration Tolerance for Thermocouple Wire:

Thermocouple type

ANSI Color Code

Initial Calibration Tolerances

Wire Alloys

Calibration

Conductor (+/-)

Jacket

Temperature Range

Standard
Limits

Special
Limits

Iron(+) vs.
Constantan(-)

J

Non color-coded

Non color-coded

0°C to +285°C
285°C to +750°C

± 2.2°C
± 0.75%

± 1.1°C
± 0.4%

CHROMEL(+) vs.
ALUMEL(-)

K

Non color-coded

Non color-coded

-200°C to -110°C
-110°C to 0°C
0°C to +285°C
285°C to +1250°C

± 2%
± 2.2°C
± 2.2°C
± 0.75%

± 1.1°C
± 0.4%

Copper(+) vs.
Constantan(-)

T

Non color-coded

Non color-coded

-200°C to -65°C
-65°C to +130°C
130°C to +350°C

± 1.5%
± 1°C
± 0.75%

± 0.8%
± 0.5°C
± 0.4%

CHROMEL(+) vs.
Constantan(-)

E

Non color-coded

Non color-coded

-200°C to -170°C
-170°C to +250°C
250°C to +340°C
340°C+900°C

± 1%
± 1.7°C
± 1.7°C
± 0.5%

± 1°C
± 1°C
± 0.4%
± 0.4%


Nominal Insulation Thickness:

Wire Size (AWG)

Conductor Insulation Thickness (mm)

Jacket Insulation Thickness (mm)

Outer Diameter (mm)

20

0.10

0.10

1.2X2.2

20 7/28

0.10

0.10

1.2X2.2

24

0.10

0.10

1.0X1.7

24 7/32

0.10

0.10

1.0X1.7

26

0.10

0.10

0.9X1.6

28

0.10

0.10

0.8X1.5

 


FAQ:

 Q1:What's MOQ for Kapton thermocouple wire?

 A: The MOQ is 300meters according to the standard packing.

Q2:What code colors do you have?

A: ANSI,JIS,IEC.

Q3:What are your packaging specifications?

A:100meters/Roll,200meters/Roll,300meters/Roll,and also can packing as customer requested.

Q4: How can I get a sample?
A:Please feel free to contact us by email the samples, we are honored to offer your samples as you request.

Q5: When will you make the delivery?
A: In general, the leading time is 10 days to 15 days. But please confirm the exact delivery time with us as different products and different quantity will have different leading time.

 



Hot Tags: kapton insulated copper thermocouple wire, China, suppliers, manufacturers, factory, buy, customized, price, pricelist, quotation

Send Inquiry